Diesel Generator Sets

2,000kW

Request Quote
KEY SPECS

 

Model

GSBD22000L-UL

 

Engine Brand

Baudouin

 

Engine Model

20M33G4D2/6

 

Alternator

Leroy Somer

 

Generator Controller

DSE 7310

Features at a Glance

Engine
20M33G4D2/6
Alternator
LS842-S60
Voltage
480/277
Phases
3
Frequency
60Hz
Standby Power
2000kW/2500 KVA
Power Factor
0.8
Current (Amps)
3010
Brand
Baudouin
Model
20M33G4D2/6
Exhaust Emissions
Tier 2
RPM
1800
Standby Rating (kWm)
2230
Standby Rating (bhp)
2991
Prime Rating (kWm)
2027
Prime Rating (bhp)
2718
Number of Cylinders
20
Aspiration
Turbocharged and Aftercooled
Displacement
3991
Engine Air Flow (CFM)
6173
Governor Type
Electronic
Control Voltage
24V
Bore /Stroke
5.91X7.28(150X185)
Cooling Capacity w/o Radiator
37
Oil Capacity
62
Brand
Leroy Somer
Model
LSA842-S60 / LS 842M70
Frequency
60Hz
Phases
3
Winding Leads
12
Insulation System
H Class
Control System
Separately Excited by P.M.G.
Protection
IP23
Power Factor
0.8
Coolling Air (CFM)
Voltage Regulation
+-0.5%

The DSE7310 MKII is an Auto Start Control Module and the DSE7320 MKII is an Auto Mains (Utility) Failure Control Module suitable for a wide variety of single, diesel, or gas genset applications.

Monitoring an extensive number of engine parameters, the modules will display warnings, shutdown, and engine status information on the backlit LCD screen, illuminated LEDs, remote PC, and via SMS text alerts (with external modem).

The DSE7320 MKII will also monitor the mains (utility) supply.
The modules include USB, RS232, and RS485 ports, as well as dedicated DSE Net® terminals for system expansion.

Key Features

  • 4-line backlit LCD text display
  • Multiple display languages
  • Five-key menu navigation
  • LCD alarm indication
  • DSENet® expansion compatibility
  • Internal PLC editor
  • Protections disable feature
  • Fully configurable via PC using USB, RS232, and RS485 communication
  • Front panel configuration with PIN protection
  • Power save mode
  • 3-phase generator sensing and protection
  • 3-phase mains (utility) sensing and protection (DSE7320 MKII only)
  • Automatic load transfer control (DSE7320 MKII only)
  • Generator current and power monitoring (kW, kVar, kVA, pf)
  • Mains current and power monitoring (kW, kVar, kVA, pf) (DSE7320 MKII only)
  • kW and kVar overload and reverse power alarms
  • Overcurrent protection
  • Unbalanced load protection
  • Independent earth fault protection
  • Breaker control via fascia buttons
  • Fuel and start outputs configurable when using CAN
  • 6 configurable DC outputs
  • 2 configurable volt-free relay outputs
  • 6 configurable analog/digital inputs
  • Support for 0–10V and 4–20mA sensors
  • 8 configurable digital inputs
  • Configurable 5-stage dummy load and load shedding outputs
  • CAN, MPU, and alternator frequency speed sensing in one variant
  • Real-time clock
  • Manual and automatic fuel pump control
  • Engine pre-heat and post-heat functions
  • Engine runtime scheduler
  • Engine idle control for starting and stopping
  • Fuel usage monitor and low fuel level alarms
  • Simultaneous use of RS232 and RS485 communication ports
  • True dual mutual standby using RS232 or RS485 for accurate engine hours balancing
  • MODBUS RTU support with configurable MODBUS pages
  • Advanced SMS messaging (additional external modem required)
  • Start and stop capability via SMS messaging
  • 3 configurable maintenance alarms
  • Compatible with a wide range of CAN engines, including Tier 4 engine support
  • Uses DSE Configuration Suite PC software for simplified configuration
  • License-free PC software
  • IP65 rating (with supplied gasket) offers increased resistance to water ingress
  • Modules can be integrated into building management systems (BMS) using MODBUS RTU

Key Benefits

  • Automatically transfers between mains (utility) and generator (DSE7320 MKII only) for convenience
  • Hours counter provides accurate information for monitoring and maintenance periods
  • User-friendly setup and button layout for ease of use
  • Multiple parameters are monitored and displayed simultaneously for full visibility
  • The module can be configured to suit a wide range of applications for user flexibility
  • PLC editor allows user-configurable functions to meet specific application requirements

Acoustic enclosure designed and manufactured with 14-gauge carbon steel sheet, polyurethane acoustic coating, access and air expulsion to avoid gas accumulation, and a drainage system to prevent liquid accumulation. Electrostatic painting for extended life. Aluminum and stainless steel enclosure options are also available.

UL Listed

ISO 9001

ISO 14001

OHSAS 18001

ISO 8528

ISO 3046

AS 2789

DIN 6271

BS 5514

Includes comprehensive post-sale support, starting with detailed operation and maintenance manuals for easy setup and ongoing service. It’s backed by a 24-month / 1,000-hour limited standby warranty covering defects in materials and workmanship. Optional maintenance and repair agreements are also available to ensure long-term reliability and minimize downtime.

Standby Power

Load
Gal./hr.
L/hr.
100%
154.1
583.7
75%
106.38
402.7
50%
72.17
273.2
25%
39.91
151.1

Open Genset

Length (in.)
253.3
Width (in.)
108.5
Height (in.)
129.2

Enclosed Genset

Length (in.)
358.3
Width (in.)
118.1
Height (in.)
143.8
  • DSE 9470 Battery Charger
  • Battery and Battery Rack
  • ABB Main Line Circuit Breaker
  • Hotstart Pre-heater 2 RMP-CSM10902-000
  • Residential Grade Silencer Open Unit
  • Critical Grade Silencer Inside Enclosure
  • Emergency Stop Button
  • Flex Fuel Lines
  • Protection Covers for Rotating Parts
  • Exhaust Insulation Cover
  • Anti-Vibration Pads between Engine/Alternator & Base Frame
  • Operation and Maintenance Manuals
  • 24 Months / 1000 Hours Limited Standby Warranty
  • Paralleling Adder (DSE8610 & Motorized Breaker)
  • 120V GFCI Receptacle
  • 240V Receptacle
  • Alternator Strip Heater
  • Battery Blanket Heater
  • Battery Disconnect Switch
  • Battery Pad Heater
  • Battery Restraint
  • Control Panel Heater
  • DSE2157 Output Module (8 dry contacts)
  • DSE2520 Remote Display Module
  • DSE2548 Remote Annunciator (16 light)
  • DSE2548 Remote Annunciator (24 light)
  • DSE2548 Remote Annunciator (8 light)
  • DSE890 3G Gateway
  • GSM/GPS Antenna – 3M RG-174, GSM-SMA(M), GPS-SMA(F)
  • DSE9641 10A Battery Charger
  • DSE9470 10A Battery Charger
  • Enclosure AC Light and On/Off Switch
  • Enclosure DC Light and On/Off Switch
  • Enclosure Space Heater (1500W / 120V)
  • Load Center / Distribution Board (100A, 12 Breaker)
  • Load Center / Distribution Board (200A, 8 Breaker)
  • AVR Upgrade
  • Oil Pan Heater
  • Relay – 10A Common Alarm
  • Relay – 10A Run
  • Remote E-Stop – Breaker Glass Type / NEMA 3R
  • Remote E-Stop – Breaker Glass Type / NEMA 4X
  • Remote E-Stop – Flush Mount
  • Remote E-Stop – Surface Mount
  • Remote E-Stop – Visual / Plastic Hinged Cover
  • Spring Isolator – Non-Seismic (ACE 121 Series) – Skirt Not Included
  • Spring Isolator – Seismic / Restraint (ACE 821 Series) – Skirt Not Included
  • Voltage Adjust Rheostat
  • Automatic Transfer Switch
  • UL 142 Sub-base Tank with 4,700 Gallon Fuel Capacity @ 24 Hr.

Download Resources

Network Environments product documents are available to support your data center requirements.

GSBD22000L-UL Spec Sheet